ホーム > ブログ> Single plunger pump hydraulic system what are the common faults?

Single plunger pump hydraulic system what are the common faults?

September 01, 2024
Single piston pump hydraulic system common fault can not increase the load can not be increased, the heavy load can not be improved, in the analysis of single piston pump hydraulic system failure, according to different components, divided into different sections, the first A section of the tank, pump, the second section is the cylinder. The following is about the single plunger pump hydraulic system analysis of common failures. Single piston pump hydraulic system what are the common faults? A single piston pump hydraulic system load can not improve the situation of failure Loose the pump and cylinder connections pipeline joints, observe the pump work. If the pump oil, indicating the normal operation of the first section; the other hand, that the first section is faulty. 1. The first section of the case of failure (1) separation block stuck. The clutch handle placed in the joint position to see the top of the separation axis drop situation, such as the whereabouts of incomplete, indicating the separation block stuck. In this case, loosen slightly the three bolts of the oil pump and move the oil pump slightly to eliminate the jamming of the separation block, and then tighten the three bolts evenly. (2) too little hydraulic oil, the tank lack of oil. Can be observed through the transparent plastic pipe of the low-pressure oil line, or release the low-pressure oil pipe joint. If the oil level is too low, add hydraulic oil. (3) A serious oil leak, such as one-way valve sealing surface uneven or clutter; safety valve steel ball seal ring damaged or stuck into the stolen goods, etc., can make the pump does not pump oil. To clean the booty or grinding to restore its sealing performance. (4) The first gearbox can not rotate normally. For example, a serious clutch slippery, clutch pedal in a separate position, the pump lost power, of course, can not rotate. (5) Low-pressure oil into the large amount of air, air bubbles impede the flow of hydraulic oil, can be seen directly. Release the check valve nut to remove the air. (6) 108 bearing ring broken, ball off, broken debris stuck in the variable speed gear, the driver did not hear the sound of damage, the plunger will not pump oil. At this point should remove the pump observation, if the 108 bearing is broken, gear oil should be released to completely remove debris, and then replace the 108 bearings. (7) plunger stuck in the pump body, clutch clutch handle by hand, judging whether the plunger stuck. If the separation is easy, the plunger spring is in compression and the plunger is stuck in the pump body. Plunger stuck for three reasons: ① longer working pressure pump, a larger load, or a long time "empty pump", or with the gap is too small, poor lubrication, high temperature and other reasons can cause the plunger stuck. If the serious injury, should be replaced by a new pump; If the minor injuries, the application of fine abrasive cloth polished to the Department of polished, can continue to use. ② newly installed pump prone to plug the phenomenon of the plunger, which is mainly fixed pump three bolts caused by inconsistent tightening torque, the three bolts can be slightly tightened. Move the pump slightly and tighten the three bolts evenly. ③ more impurities in the hydraulic oil, so that the plunger and pump body surface damage and stuck. 2. The second section of the case of failure (1) connecting rod and inner lifting arm connecting pin broken, connecting rod off, the lifting arm can not get power. The diagnosis is: When the hydraulic pump is working normally, lift the outer lifting arm several times by hand and feel whether the inner lifting arm pushes the piston. If there is no sense of force, the lifting arm and the connecting rod can be basically determined to be disconnected. At this point the cover should be disassembled inspection, if it is within the lifting arm and the connecting rod connecting rod break, you can replace a slightly smaller pin, so that the pin does not directly withstand the force, leaving the connecting rod spherical surface and lift arm concave direct contact Power transmission, or pin will continue to break. After connecting the connecting rod and the inner lifting arm to break the pin, the connecting rod spherical surface may directly overhang the edge of the pit of the lifting arm, which is equivalent to lengthening the connecting rod. Pistons can not lift to reach the drain position on time, therefore, the connecting rod may break the inner lifting arm, or even breach the back cover. This failure occurs with a certain noise, once found, should immediately stop, replace the new pieces. (2) The cylinder and the piston stuck, the hydraulic oil is too dirty, pulling the piston and the cylinder wall; or piston and cylinder liner gap is too small, working time is longer, the temperature is higher, the piston swelled in the cylinder sleeve. Diagnosis is: When the pump is working properly, release the tubing joint between the pump and the cylinder, you can find that there is high pressure oil spray, but the outer lift arm without lifting action. Exclusion method is: decomposition cylinder. If cylinder and piston are damaged seriously, should be replaced with new ones. If the strain is light, use fine emery cloth to polish the injury and re-install. Second, the single piston pump hydraulic system appears heavy load can not improve the situation 1. The first section of the fault situation (1) safety valve to adjust the pressure is low, to correct the pressure relief valve. (2) Plunger and pump body with serious wear and tear, this phenomenon is mainly the hydraulic system using a longer time. The general accumulated working time of more than 1500h, with a small diameter dial gauge, with the maximum gap of not more than 0. 03mm. If the clearance is too large, it will affect the plunger pump oil, causing oil leakage or air intake. (3) mixed with air in the hydraulic oil should be excluded. (4) safety valve steel ball sealing surface dirt or seal itself, especially the one-way valve. Check valve body under the plane and the pump body contact between the sealing surface dirt, should be removed. Seal the valve body surface should be polished in a smooth cloth to restore its sealing. 2. The second section of the case of failure (1) the top of the piston seal drain ball leak seal function, a serious oil spill, this fault is not easy to judge in the outside, only to break down the cylinder for inspection. (2) piston and cylinder wear serious seal ring is severely damaged or severely damaged, resulting in oil spills, affecting the lifting force. (3) cylinder into the top of the loose tube, causing serious oil spills. If the cylinder screw holes on the slider, should be replaced with a new cylinder. Extended reading: Top ten brands of motorcycles Canton Fair Central China Construction Water Exhibition Pump manufacturers ranked ptc exhibition industry Internet (Xiamen) Technology Co., Ltd. Asia Pump Network Editor: He Duanhui (QQ / WeChat:) http: //beng.liuti. cn / (Service Hotline:)
お問い合わせ

Author:

Ms. Alice

Eメール:

info@dyhydr.com

Phone/WhatsApp:

+8617616058688

人気商品
You may also like
Related Categories

この仕入先にメール

タイトル:
イーメール:
メッセージ:

Your message must be betwwen 20-8000 characters

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

送信