ホーム > ブログ> Hydraulic shock in Dalan Hydraulic Analysis Hydraulic Pumping Station

Hydraulic shock in Dalan Hydraulic Analysis Hydraulic Pumping Station

July 28, 2023
The hydraulic shock in the hydraulic pump station is difficult to avoid. The hydraulic shock refers to the sudden change of the pressure caused by the sudden change of the hydraulic oil in the hydraulic pump station. The hydraulic shock may damage some hydraulic components in the hydraulic pump station. The reason is that when a hydraulic shock occurs, the partial pressure may rise several times or several times in an instant.
The hydraulic shock in the hydraulic pump station is difficult to avoid. The hydraulic shock refers to the sudden change of the pressure caused by the sudden change of the hydraulic oil in the hydraulic pump station. The hydraulic shock may damage some hydraulic components in the hydraulic pump station. The reason is that when a hydraulic shock occurs, the partial pressure may rise several times or several times in an instant.

Therefore, Dalan Hydraulics recommends suppressing the hydraulic shock and estimating the maximum hydraulic shock that may cause damage to the hydraulic pumping station. It is very important.

There are many reasons for hydraulic shocks. Here we talk about the two most common ones:

1. The hydraulic shock caused by the sudden opening and closing of the valve, due to the inertia of the hydraulic oil and the compressibility of the oil, will cause the kinetic energy of the hydraulic oil to rapidly change into pressure energy. This dramatic change will generate pressure waves. It is called “water hammer”, but due to the viscosity of the hydraulic oil, this phenomenon will stop for a short time.

2. The hydraulic shock caused by the sudden start or sudden stop of the hydraulic pump station, because the equipment and hydraulic oil have inertia, the hydraulic shock generated by this situation is also very large.

There are three ways to suppress hydraulic shock:

1. Smoothly open and close the valve so that there is no excessive hydraulic shock. Or change the manual reversing valve to an electromagnetic reversing valve.

2. The hydraulic pump station should be preheated before starting. Do not use the maximum power from the beginning.

3. The safest way is to install an accumulator so that it can prevent damage to the hydraulic system even if it is hydraulically impacted.








----- Editor-in-Chief: Dalan Oil Pump Motor 02-Procurement Consultant

Copyright http: / (Dalan Motor) Reprint, please indicate the source

Http://news.chinawj.com.cn Editor: (Hardware Business Network Information Center) http://news.chinawj.com.cn
お問い合わせ

Author:

Ms. Alice

Eメール:

info@dyhydr.com

Phone/WhatsApp:

+8617616058688

人気商品
You may also like
Related Categories

この仕入先にメール

タイトル:
イーメール:
メッセージ:

Your message must be betwwen 20-8000 characters

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

送信