ホーム > ブログ> High-pressure piston pump repair _ High-pressure piston pump Frequently Asked Questions

High-pressure piston pump repair _ High-pressure piston pump Frequently Asked Questions

September 08, 2024
High Pressure Piston Pump Maintenance _ High pressure piston pump often appear in the use of various problems, to bring a lot of trouble life. Then how do we find and eliminate these failures in time? High-pressure piston pump repair _ High-pressure piston pump Frequently Asked Questions High-pressure piston pump repair - Can not start First check the power supply situation: the connection is solid; switch contact is tight; Fuse Whether it is blown; whether the three-phase power supply is equal or not. If there is an open circuit, poor contact, the fuse blown, lack of phase, should identify the cause and timely repair. Second check whether the high-pressure plunger pump mechanical failure, common reasons are: packing is too tight or between the impeller and the pump is clogged with debris; pump shaft, bearing rust; severe shaft bending and so on. Remedy: Loose packing, clear the diversion trough; Disassemble the pump to remove debris and rust; Remove the pump shaft to correct or replace the new pump shaft. High Pressure Piston Pump Repair - Severe vibration mainly for the following reasons: Electric Rotor Unbalance; Coupling poor; Bearing wear and tear; Rotating parts of the loose, broken; Pipe stent is not strong and other reasons. Can be taken to adjust, repair, reinforcement, straightening, replacement and other methods. The above is the common cause of the failure of the high-pressure piston pump, in practice, to deal with the failure, due to the actual analysis, should follow the principle of the first outside the rear. High-pressure piston pump repair - Deep submersible high pressure piston pump is not on the water or small amount of water First Take a look at the difference between the current running on the high-pressure piston pump and the current during normal operation. If the running time than usual (basically the usual current of 23), then there is impeller wear, the top of the pump head check valve blockage and other issues. If the current in peacetime is the same, then it is the gasket leakage, pipe leakage, pump leakage and other issues. If the current is greater than usual when running, it is basically OK to wear the problem of wearing parts. In addition, if the cable is broken, the amount of water is the same as usual, but the current will be larger. 3 380V motor current is generally 2.2A. As long as the above reasons are often repaired deep well pump repair staff can be found out. High-pressure piston pump repair - suction is not due to the water pump body air or inlet gas, or the bottom valve is not strict Irrigation filling dissatisfaction, vacuum pump packing serious leaks, sluice gate or shot closed lax. Remedy: First water pressure up, and then filled with water pump, and then boot. At the same time check the check valve is tight, piping, fittings leaks, such as found leakage, remove the joint at the joints coated with oil or paint, and tighten the screws. Check the high pressure piston shaft oil seal ring, such as serious wear and tear should be replaced by new parts. Piping leaks or leaks. Nuts may not be tightened during installation. If the leakage is not serious, can be smeared in the place of leakage or leakage of cement, or coated with asphalt mixture of cement slurry. Temporary repair can be painted wet mud or soft soap. If the joint leaks, you can use a wrench to tighten the nut, such as serious leakage must be re-disassembly, replacement of cracked pipe; reduce the head, the high-pressure plunger pump nozzle into the water 0.5m. (Editor: cloud sea)
お問い合わせ

Author:

Ms. Alice

Eメール:

info@dyhydr.com

Phone/WhatsApp:

+8617616058688

人気商品
You may also like
Related Categories

この仕入先にメール

タイトル:
イーメール:
メッセージ:

Your message must be betwwen 20-8000 characters

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

送信